The short answer
In NSW, a deck needs a continuous balustrade (the NCC calls it a barrier) along any side where it is possible to fall 1 m or more from the deck surface to the surface below. The balustrade must be at least 1 m high above the deck floor, and no opening in it may let a 125 mm sphere pass through. Where the fall is more than 4 m, horizontal parts between 150 mm and 760 mm above the floor must not make it easy to climb. These rules come from Part 11.3 of the ABCB Housing Provisions, part of the National Construction Code (NCC), and they apply whether or not the deck needed council approval.
Which code applies in NSW
NSW currently uses NCC 2022. The current edition is NCC 2022 Amendment 2, in effect from 29 July 2025, according to Building Commission NSW. NSW will adopt NCC 2025 on 1 May 2027. NCC 2025 keeps the same barrier, opening, climbability and handrail numbers, so the figures on this page hold through that change.
The detailed rules are in the Housing Provisions, Part 11.3. Following Part 11.3 meets performance requirement H5P2 in NCC Volume Two. A builder may instead use a Performance Solution that meets the performance requirements.
When a balustrade is required
Clause 11.3.3(1) requires a continuous barrier along the side of a trafficable surface, such as a deck, "where it is possible to fall 1 m or more measured from the level of the trafficable surface to the surface beneath".
The trigger is 1 m or more. A deck sitting exactly 1 m above the ground below needs a balustrade. The fall is measured to whatever surface is beneath, so a deck over a slope, a retaining wall or a sunken path can need a balustrade on one side and not the other.
Clauses 11.3.3 and 11.3.4 name decks directly, so the rules apply to a deck whatever building class the certifier gives it.
Balustrade dimensions
| Rule | Requirement | Clause |
|---|---|---|
| When required | Possible fall of 1 m or more to the surface beneath | 11.3.3(1) |
| Height on decks, landings and balconies | At least 1 m above the floor | 11.3.4(2) |
| Height on stairs and ramps | At least 865 mm above stair nosings or ramp floor | 11.3.4(2) |
| Openings | Must not allow a 125 mm sphere to pass through | 11.3.4(4) |
| Gap to the side face of a deck or stair | Not more than 40 mm | 11.3.4(5) and (6) |
| Climbability, fall of more than 4 m | Horizontal elements between 150 mm and 760 mm above the floor must not facilitate climbing | 11.3.4(8) |
| Wire balustrades | Wires no more than 2.5 mm diameter, supports no more than 900 mm apart, tension and deflection to Table 11.3.6 | 11.3.6 |
| Loads | Designed to AS/NZS 1170.1 | 11.3.4 |
A few points on these:
- The 125 mm rule covers decorative balustrades too. Patterned panels, slats and gaps under the bottom rail all count. On stairs, openings are measured above the line of the tread nosings.
- Side-fixed balustrades. Where posts or panels are fixed to the face of the deck or stair rather than on top, the gap between the balustrade and the face must not exceed 40 mm.
- Climbability. Above a 4 m fall, horizontal rails or slats in the 150 mm to 760 mm zone can be climbed like a ladder. Vertical balusters avoid that problem.
- Glass. Glass barriers must also comply with H1D8. We do not build glass pool fencing.
Handrails on deck stairs
Handrails are covered by clause 11.3.5:
- a handrail is required on at least one side of a stair flight or ramp, for its full length;
- its top must be at least 865 mm above the stair nosings;
- it must be continuous, with nothing that breaks a handhold, although newel posts are allowed;
- a handrail is not required where the change in level is less than 1 m.
A stair can need both a handrail and a balustrade. Our deck stair rules guide covers riser heights, treads and landings.
Exempt decks still need a balustrade
Some low decks can be built as exempt development, without council approval. Section 1.16 of the Codes SEPP still requires exempt work to meet the Building Code of Australia deemed-to-satisfy provisions, so the balustrade rules apply. The NSW Government states that "balconies, decks, balustrades and railings must be built to the Building Code of Australia" and relevant Australian Standards, and that "they must be inspected and maintained regularly for safety". See deck council approval in NSW for the exempt limits.
Privacy screens on decks
A privacy screen fixed to a deck is a separate item under the Codes SEPP (Subdivision 31). To be exempt it must be at least 1.7 m and no more than 2.2 m above the finished floor level, no longer than 5 m, at least 900 mm from each boundary, in the rear yard, and not attached to a boundary fence or retaining wall. A lot may have no more than 2. Under the Inland Code, a raised deck within 6 m of a boundary may also need a privacy screen as a CDC condition.
Checking an existing balustrade
You can check your own balustrade for the obvious problems. The NSW Fair Trading deck and balcony safety guide suggests pushing and pulling on handrails and balustrades to check for movement. Look for:
- posts or rails that move when you push on them;
- rusted, bent or broken bolts, screws and brackets;
- soft or rotting timber at post bases and where rails join;
- gaps wider than a 125 mm sphere, for example missing balusters or a lifted bottom rail.
If you find movement or rot, keep people off that edge and have it inspected. Balustrade repairs are structural work for a licensed builder. See signs your deck needs repair.
How we build balustrades
Addan builds balustrades to the Part 11.3 numbers: at least 1 m high on the deck, no opening that passes a 125 mm sphere, and infill that meets the climbability rule where the fall is more than 4 m. Where a design needs engineering, we arrange an engineer. See deck stairs and balustrades or call Addan on 0476 217 422 for a free on-site quote.
Common questions
What height does a deck balustrade need to be in NSW?
At least 1 m above the deck floor. On stairs, the balustrade must be at least 865 mm above the line of the stair nosings.
At what height does a deck need a balustrade?
Where it is possible to fall 1 m or more from the deck surface to the surface below. That includes a deck that is exactly 1 m above the ground.
What is the maximum gap between balusters?
Openings must not allow a 125 mm sphere to pass through. This applies to decorative balustrades too, and on stairs the gap is measured above the line of the nosings.
Can I have horizontal slats on my deck balustrade?
Where the possible fall is 4 m or less, the NCC climbability rule does not apply, though the 125 mm opening rule does. Where the fall is more than 4 m, horizontal elements between 150 mm and 760 mm above the floor must not facilitate climbing.
Do deck stairs need a handrail?
Yes, on at least one side for the full length of the flight, with the top at least 865 mm above the nosings. A handrail is not required where the change in level is less than 1 m.
Does NCC 2025 change the balustrade rules?
NSW adopts NCC 2025 on 1 May 2027. It keeps the same barrier, opening, climbability and handrail numbers for houses.