The short answer
If your property is mapped as bush fire prone land, a deck may need to meet construction requirements under AS 3959 for the site's Bushfire Attack Level (BAL). An exempt deck or pergola less than 5 m from a dwelling must be made of non-combustible material, so a timber deck close to the house will usually need a CDC or DA instead. Complying development is not allowed on BAL-40 or BAL-FZ land, apart from limited exceptions. Merbau, Spotted Gum and Blackbutt are listed as bushfire-resisting timbers for BAL-12.5, BAL-19 and BAL-29. Check your property's status with the NSW RFS online tool, and confirm the requirements for your site with council or your certifier.
Is your property bush fire prone
Use the NSW RFS bush fire prone land check and enter your address. The result is only valid on the day of the search, and the tool does not give a BAL. A council planning certificate (section 10.7) confirms the official status.
Wagga Wagga City Council publishes a bush fire prone land map for the city, prepared by the RFS and dated 5 December 2022. Properties on the city fringes, rural blocks and lots near grassland or bush are the ones to check. Use the RFS tool for the current position rather than relying on an older map.
The six Bushfire Attack Levels
A BAL describes how exposed a building is to a bush fire. The NSW RFS describes the six levels as:
| BAL | RFS description |
|---|---|
| BAL-LOW | "Lowest risk from a potential fire" |
| BAL-12.5 | "Risk is primarily from potential embers during a fire" |
| BAL-19 | "Moderate risk, particularly from embers and burning debris" |
| BAL-29 | "High risk, particularly from embers, debris and heat" |
| BAL-40 | "Very high risk. Likely to be impacted by embers, debris, heat and potentially flames" |
| BAL-FZ | "Extreme risk. Directly exposed to the flames of a potential fire front" |
Source: NSW RFS, your level of risk.
The standards that apply
AS 3959, Construction of buildings in bushfire-prone areas, sets construction requirements for each BAL. The current edition is AS 3959:2018.
Planning for Bush Fire Protection 2019 (PBP 2019) is the legislated NSW document. It was adopted on 1 March 2020 and still applies. A draft PBP 2026 was exhibited from 6 August to 3 September 2026, but the RFS says it "cannot be used or relied upon" until it is published and recognised in law.
The detailed AS 3959 rules for decks, such as enclosed subfloors, distance from glazing and decking at the higher BALs, vary with the BAL and the design. Ask council or your certifier how the BAL for your site will be determined and what it requires for your deck.
Approval pathways on bush fire prone land
| Pathway | Bush fire rule | Source |
|---|---|---|
| Exempt development | A deck or pergola less than 5 m from a dwelling must be constructed of non-combustible material | Codes SEPP s 2.12(1)(n) |
| Complying development (CDC) | Not allowed on BAL-40 or BAL-FZ land, except non-habitable detached development more than 6 m from any dwelling, or non-combustible fences | Codes SEPP s 1.19A |
| Development application (DA) | Needed where the deck is neither exempt nor complying | Wagga Wagga City Council decides it |
The exempt rule is the one that catches people out. A timber deck attached to the house is less than 5 m from a dwelling, so on bush fire prone land it cannot be exempt, even if it meets every other standard. It then needs a CDC or a DA. See deck council approval in NSW and pergola council approval in NSW for the other limits.
Other bush fire rules in the Codes SEPP:
- an exempt fence on bush fire prone land must be made of non-combustible materials or hardwood;
- an exempt awning must use non-combustible materials;
- an exempt carport less than 5 m from a dwelling must be non-combustible.
Bushfire-resisting timbers
WoodSolutions Technical Design Guide 21 lists Merbau, Spotted Gum and Blackbutt as bushfire-resisting timbers for BAL-12.5, BAL-19 and BAL-29. AS 3959 lists seven bushfire-resisting timbers: Blackbutt, Kwila (Merbau), Red Ironbark, River Red Gum, Silvertop Ash, Spotted Gum and Turpentine.
All three hardwoods we offer for decks are on that list. That makes a hardwood deck a practical option on many bush fire prone sites up to BAL-29, subject to the full AS 3959 requirements for the design. Treated pine is not on the bushfire-resisting list. For composite boards, check the manufacturer's documents for any BAL rating. See hardwood decks and the best decking timber.
At BAL-40 and BAL-FZ, requirements are stricter and complying development is not available for most deck work. Get advice from council or a certifier early.
How we handle it
At the quote, Addan checks whether your property is mapped as bush fire prone. If it is, we work out the approval pathway, arrange the certifier and any engineering, and build to the materials and details the approval requires. Addan is not a certifier and does not assess BAL ratings. Use the instant estimate for a starting figure, or call 0476 217 422 for a free on-site quote.
Common questions
How do I find out if my property is bush fire prone?
Use the NSW RFS online tool and enter your address. The result is valid on the day of the search only, and it does not give a BAL. A council section 10.7 planning certificate confirms the official status.
Can I build a timber deck on bush fire prone land?
Often, yes, but not usually as exempt development close to the house. An exempt deck less than 5 m from a dwelling on bush fire prone land must be non-combustible, so a timber deck there needs a CDC or a DA and must meet AS 3959 for the site's BAL.
Which decking timbers are bushfire-resisting?
AS 3959 lists Blackbutt, Kwila (Merbau), Red Ironbark, River Red Gum, Silvertop Ash, Spotted Gum and Turpentine. TDG 21 lists Merbau, Spotted Gum and Blackbutt for BAL-12.5, BAL-19 and BAL-29.
Can I get a CDC for a deck on BAL-40 land?
Generally no. Complying development is not allowed on BAL-40 or BAL-FZ land, apart from non-habitable detached development more than 6 m from any dwelling and non-combustible fences. Other work needs a DA.
Is PBP 2026 in force?
No. Planning for Bush Fire Protection 2019 still applies. The draft PBP 2026 was exhibited in August and September 2026 and cannot be relied on until it is adopted.